Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Talanta ; 262: 124701, 2023 Sep 01.
Article in English | MEDLINE | ID: covidwho-2324697

ABSTRACT

Fast and effective diagnosis is the first step in monitoring the current coronavirus 2 (CoV-2) pandemic. Herein, we establish a simple and sensitive electrochemical assay using magnetic nanocomposite and DNA sandwich probes to rapidly quantify the CoV-2 nucleocapsid (N) gene down to the 0.37 fM level. This assay uses a pair of specific DNA probes. The capture probe is covalently conjugated to Au-decorated magnetic reduced graphene oxide (AMrGO) nanocomposite for efficiently capturing target RNA. In contrast, the detection probe is linked to peroxidase for signal amplification. The probes target the COV-2 gene, allowing for specific magnetic separation, enzymatic signal amplification, and subsequent generation of voltammetric current with a total assay time of 45 min. The developed biosensor has high selectivity and can discriminate non-specific gene sequences. Synthetic COV-2 N-gene can be detected efficiently in serum and saliva, while 1-bp mismatch gene yielded a low response. The performance of the genosensor was good in an extensive linear range of 5 aM-50 pM. For synthetic N-gene, we achieved the detection limit of 0.37, 0.33, and 0.19 fM in human saliva, urine, and serum. This simple, selective, and sensitive genosensor could have various genetics-based biosensing and diagnostic applications.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Nanocomposites , Humans , SARS-CoV-2/genetics , Graphite/chemistry , Nanocomposites/chemistry , Nucleocapsid , Electrochemical Techniques , Gold/chemistry
2.
Nanomaterials (Basel) ; 13(9)2023 Apr 22.
Article in English | MEDLINE | ID: covidwho-2314606

ABSTRACT

This study describes the use of copper nanoparticles (CuNPs) and reduced graphene oxide (rGO) as an electrode modifier for the determination of chloroquine phosphate (CQP). The synthetized rGO-CuNPs composite was morphologically characterized using scanning electron microscopy and electrochemically characterized using cyclic voltammetry. The parameters were optimized and the developed electrochemical sensor was applied in the determination of CQP using square-wave voltammetry (SWV). The analytical range for the determination of CQP was 0.5 to 110 µmol L-1 (one of the highest linear ranges for CQP considering electrochemical sensors), with limits of detection and quantification of 0.23 and 0.78 µmol L-1, respectively. Finally, the glassy carbon (GC) electrode modified with rGO-CuNPs was used for quantification of CQP in tap water; a study was carried out with interferents using SWV and obtained great results. The use of rGO-CuNP material as an electrode modifier was thus shown to be a good alternative for the development of low-cost devices for CQP analysis.

3.
Anal Chim Acta ; 1265: 341326, 2023 Jul 18.
Article in English | MEDLINE | ID: covidwho-2311677

ABSTRACT

Herein, we have proposed a straightforward and label-free electrochemical immunosensing strategy supported on a glassy carbon electrode (GCE) modified with a biocompatible and conducting biopolymer functionalized molybdenum disulfide-reduced graphene oxide (CS-MoS2/rGO) nanohybrid to investigate the SARS-CoV-2 virus. CS-MoS2/rGO nanohybrid-based immunosensor employs recombinant SARS-CoV-2 Spike RBD protein (rSP) that specifically identifies antibodies against the SARS-CoV-2 virus via differential pulse voltammetry (DPV). The antigen-antibody interaction diminishes the current responses of the immunosensor. The obtained results indicate that the fabricated immunosensor is extraordinarily capable of highly sensitive and specific detection of the corresponding SARS-CoV-2 antibodies with a LOD of 2.38 zg mL-1 in phosphate buffer saline (PBS) samples over a broad linear range between 10 zg mL-1-100 ng mL-1. In addition, the proposed immunosensor can detect attomolar concentrations in spiked human serum samples. The performance of this immunosensor is assessed using actual serum samples from COVID-19-infected patients. The proposed immunosensor can accurately and substantially differentiate between (+) positive and (-) negative samples. As a result, the nanohybrid can provide insight into the conception of Point-of-Care Testing (POCT) platforms for cutting-edge infectious disease diagnostic methods.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Metal Nanoparticles , Humans , Molybdenum , Biosensing Techniques/methods , COVID-19/diagnosis , Immunoassay/methods , SARS-CoV-2 , Electrochemical Techniques/methods
4.
Talanta ; 259: 124490, 2023 Jul 01.
Article in English | MEDLINE | ID: covidwho-2249477

ABSTRACT

Coronavirus disease 2019 is one of the global health problems. Herein, a highly sensitive electrochemical biosensor has been designed to detect the RNA-dependent RNA polymerase (RdRP) of the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) (SARS-CoV-2 RdRP). Herein, the surface-initiated reversible-addition-fragmentation-chain-transfer polymerization was used to amplify the electrochemical signal. To do that, the thiol-terminated peptide nucleic acid (PNA) probes were first immobilized on the surface of a screen-printed electrode modified with reduced graphene oxide-gold nanocomposite and then the fixed concentration of the SARS-CoV-2 RdRP was added to the electrode surface to interact with PNA probes. Subsequently, the Zr 4+ ions were added to interact with the phosphate groups of the SARS-CoV-2 RdRP. It allowed us to polymerase the ferrocenylmethyl methacrylate (FcMMA) and 4-cyano-4-(phenylcarbonothioylthio)-pentanoic acid on the SARS-CoV-2 RdRP chain. Since the poly-FcMMA has an electrochemical signal, the response of the PNA-based sensor to SARS-CoV-2 RdRP was increased in the range of 5-500 aM. The limit of detection was calculated to be 0.8 aM which is lower than the previous sensor for SARS-CoV-2 RdRP detection. The proposed PNA-based sensor showed high selectivity to the SARS-CoV-2 RdRP in the presence of the gene fragments of influenza A and Middle East respiratory syndrome coronavirus.


Subject(s)
Biosensing Techniques , COVID-19 , Peptide Nucleic Acids , Humans , SARS-CoV-2 , Polymerization , RNA-Dependent RNA Polymerase , Biosensing Techniques/methods , Electrochemical Techniques/methods
5.
ACS Appl Mater Interfaces ; 15(12): 15195-15202, 2023 Mar 29.
Article in English | MEDLINE | ID: covidwho-2264408

ABSTRACT

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcription-polymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.


Subject(s)
COVID-19 , Graphite , Humans , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Saliva
6.
Anal Chim Acta ; 1242: 340716, 2023 Feb 15.
Article in English | MEDLINE | ID: covidwho-2149181

ABSTRACT

In this research, by using aptamer-conjugated gold nanoparticles (aptamer-AuNPs) and a modified glassy carbon electrode (GCE) with reduced graphene oxide (rGO) and Acropora-like gold (ALG) nanostructure, a sandwich-like system provided for sensitive detection of heat shock protein 70 kDa (HSP70), which applied as a functional biomarker in diagnosis/prognosis of COVID-19. Initially, the surface of the GCE was improved with rGO and ALG nanostructures, respectively. Then, an aptamer sequence as the first part of the bioreceptor was covalently bound on the surface of the GCE/rGO/ALG nanostructures. After adding the analyte, the second part of the bioreceptor (aptamer-AuNPs) was immobilized on the electrode surface to improve the diagnostic performance. The designed aptasensor detected HSP70 in a wide linear range, from 5 pg mL-1 to 75 ng mL-1, with a limit of detection (LOD) of ∼2 pg mL-1. The aptasensor was stable for 3 weeks and applicable in detecting 40 real plasma samples of COVID-19 patients. The diagnostic sensitivity and specificity were 90% and 85%, respectively, compared with the reverse transcription-polymerase chain reaction (RT-PCR) method.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , COVID-19 , Graphite , Metal Nanoparticles , Humans , Gold/chemistry , Aptamers, Nucleotide/chemistry , Metal Nanoparticles/chemistry , COVID-19/diagnosis , Graphite/chemistry , Carbon/chemistry , Limit of Detection , Prognosis , Electrochemical Techniques/methods , Biosensing Techniques/methods , Electrodes , COVID-19 Testing
7.
Sens Actuators A Phys ; 349: 114058, 2023 Jan 01.
Article in English | MEDLINE | ID: covidwho-2122809

ABSTRACT

Stimulated by the COVID-19 outbreak, the global healthcare industry better acknowledges the necessity of innovating novel methods for remote healthcare monitoring and treating patients outside clinics. Here we report the development of two different types of graphene textile electrodes differentiated by the employed fabrication techniques (i.e., dip-coating and spray printing) and successful demonstration of ergonomic and truly wearable, single-arm diagnostic electrocardiography (SADE) using only 3 electrodes positioned on only 1 arm. The performance of the printed graphene e-textile wearable systems were benchmarked against the "gold standard" silver/silver chloride (Ag/AgCl) "wet" electrodes; achieving excellent correlation up to ∼ 96% and ∼ 98% in ECG recordings (15 s duration) acquired with graphene textiles fabricated by dip-coating and spray printing techniques, respectively. In addition, we successfully implemented automatic detection of heartrate of 8 volunteers (mean value: 74.4 bpm) during 5 min of static and dynamic daily activities and benchmarked their recordings with a standard fingertip photoplethysmography (PPG) device. Heart rate variability (HRV) was calculated, and the root means successive square difference (rMMSD) metric was 30 ms during 5 min of recording. Other cardiac parameters such as R-R interval, QRS complex duration, S-T segment duration, and T-wave duration were also detected and compared to typical chest ECG values.

8.
Chem Eng J ; 453: 139750, 2023 Feb 01.
Article in English | MEDLINE | ID: covidwho-2068756

ABSTRACT

Quantitative RT-PCR (qRT-PCR) is the most commonly used diagnostic tool for SARS-CoV-2 detection during the COVID-19 pandemic. Despite its sensitivity and accuracy, qRT-PCR is a time-consuming method that requires expensive laboratories with highly trained personnel. In this work, on-site detection of SARS-CoV-2 in municipal wastewater was investigated for the first time. The wastewater was unprocessed and did not require any prefiltration, prior spiking with virus, or viral concentration in order to be suitable for use with the biosensor. The prototype reported here is a reduced graphene oxide (rGO)-based biosensor for rapid, sensitive and selective detection of SARS-CoV-2. The biosensor achieved a limit of detection (LOD) of 0.5 fg/mL in phosphate-buffered saline (PBS) and exhibited specificity when exposed to various analytes. The response time was measured to be around 240 ms. To further explore the capabilities of the biosensor in real clinical and municipal wastewater samples, three different tests were performed to determine the presence or absence of the virus: (i) qRT-PCR, (ii) a rapid antigen-based commercially available test (COVID-19 Test Strips), and (iii) the biosensor constructed and reported here. Taken together, our results demonstrate that a biosensor that can detect SARS-CoV-2 in clinical samples as well as unfiltered and unprocessed municipal wastewater is feasible.

9.
Journal of Electroanalytical Chemistry ; : 116579, 2022.
Article in English | ScienceDirect | ID: covidwho-1914587

ABSTRACT

A direct, simple and sensitive method based on electrochemical deposition of reduced graphene oxide (rGO) on a glassy carbon electrode (GCE) using cyclic voltammetry (CV) was developed for Molnupiravir (MOL) quantitative analysis. Here, the electrochemical oxidation of MOL was examined using square wave voltammetry (SWV) and a well-defined peak at 0.2 V was measured against the Ag/AgCl reference electrode with the rGO sensor in Britton-Robinson pH 9 buffer. Various operational parameters for MOL analysis such as pH of supporting electrolyte, instrumental parameters, electro polymerization cycles, and GO concentration were optimized. The sensor exhibited a linear range from 0.09 to 4.57 μM with a detection limit of 0.03 µM. The electrochemical response of the rGO sensor was characterized by electrochemical impedance spectroscopy and CV. The character of current and reversibility of the electrode reaction, the number of electrons and protons transferred were studied by the CV method. The developed sensor using the rGO sensor was validated according to the guidelines of ICH. Validation parameters, such as stability, linearity, sensitivity, accuracy, precision, recovery, robustness and ruggedness were evaluated according to the International Council for Harmonisation (ICH) [1]. The developed sensor was successfully applied for the quantification of MOL in capsule formulations.

10.
Diamond and Related Materials ; : 109093, 2022.
Article in English | ScienceDirect | ID: covidwho-1850932

ABSTRACT

Graphene-based materials present a high surface area and can present several structural defects or heteroatoms depending on the fabrication method. Such properties facilitate the graphene interaction with biomolecules leading to high electrochemical activity. In this context, we synthesize a high-quality dispersed reduced graphene oxide using Lysozyme as a dispersant (Ly-RGO). In this study, we have investigated the graphite oxidation-reduction fabrication process using X-ray Photoelectron Spectroscopy, X-ray Diffraction, and Raman Spectroscopy. We have used the Ly-RGO to fabricate an electrode on an electrochemical cell in which voltammograms show significant transduction of electrical signals. Finally, cyclic voltammetry and chronoamperometry measurements were performed with human saliva and SARS-CoV-2 RNA samples, to calibrate our biosensor. The results indicate that Ly-RGO has great potential in biosensor devices.

11.
ACS Appl Mater Interfaces ; 14(8): 10844-10855, 2022 Mar 02.
Article in English | MEDLINE | ID: covidwho-1692677

ABSTRACT

The widespread and long-lasting effect of the COVID-19 pandemic has called attention to the significance of technological advances in the rapid diagnosis of SARS-CoV-2 virus. This study reports the use of a highly stable buffer-based zinc oxide/reduced graphene oxide (bbZnO/rGO) nanocomposite coated on carbon screen-printed electrodes for electrochemical immuno-biosensing of SARS-CoV-2 nuelocapsid (N-) protein antigens in spiked and clinical samples. The incorporation of a salt-based (ionic) matrix for uniform dispersion of the nanomixture eliminates multistep nanomaterial synthesis on the surface of the electrode and enables a stable single-step sensor nanocoating. The immuno-biosensor provides a limit of detection of 21 fg/mL over a linear range of 1-10 000 pg/mL and exhibits a sensitivity of 32.07 ohms·mL/pg·mm2 for detection of N-protein in spiked samples. The N-protein biosensor is successful in discriminating positive and negative clinical samples within 15 min, demonstrating its proof of concept used as a COVID-19 rapid antigen test.


Subject(s)
Antigens, Viral/analysis , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/analysis , Graphite/chemistry , Nanocomposites/chemistry , Zinc Oxide/chemistry , Antibodies, Immobilized/immunology , Antigens, Viral/immunology , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Coronavirus Nucleocapsid Proteins/immunology , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Electrodes , Humans , Immunoassay/instrumentation , Immunoassay/methods , Limit of Detection , Phosphoproteins/analysis , Phosphoproteins/immunology , Proof of Concept Study , SARS-CoV-2/chemistry
12.
Materials (Basel) ; 14(22)2021 Nov 19.
Article in English | MEDLINE | ID: covidwho-1534159

ABSTRACT

Graphene and its derivatives, such as graphene oxide (GO) or reduced graphene oxide (rGO), due to their properties, have been enjoying great interest for over two decades, particularly in the context of additive manufacturing (AM) applications in recent years. High-impact polystyrene (HIPS) is a polymer used in 3D printing technology due to its high dimensional stability, low cost, and ease of processing. However, the ongoing development of AM creates the need to produce modern feedstock materials with better properties and functionality. This can be achieved by introducing reduced graphene oxide into the polymer matrix. In this study, printable composite filaments were prepared and characterized in terms of morphology and thermal and mechanical properties. Among the obtained HIPS/rGO composites, the filament containing 0.5 wt% of reduced graphene oxide had the best mechanical properties. Its tensile strength increased from 19.84 to 22.45 MPa, for pure HIPS and HIPS-0.5, respectively. Furthermore, when using the HIPS-0.5 filament in the printing process, no clogging of the nozzle was observed, which may indicate good dispersion of the rGO in the polymer matrix.

13.
Chemosphere ; 291(Pt 3): 132995, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1520761

ABSTRACT

The latent dangers of waterborne viral transmission have become a major public health concern. In this study, reduced graphene oxide (rGO)-Fe3O4 nanoparticles were decorated with cetyltrimethylammonium bromide (CTAB) to adsorb severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike pseudovirus and three human enteric viruses (HuNoV, HRV, and HAdV). The successful combination of CTAB with rGO-Fe3O4 was confirmed by transmission electron microscopy, X-ray diffraction, Fourier-transform infrared spectroscopy, zeta potential, Brunner-Emmet-Teller, and vibrating sample magnetometer measurements. The adsorption of HuNoV and HAdV followed pseudo-first-order kinetics, while that of HRV conformed to the pseudo-second-order model. CTAB-functionalized rGO-Fe3O4 exhibited exceptionally high adsorption of HuNoV, HRV, HAdV and SARS-CoV-2 spike pseudovirus, with maximum adsorption capacities of 3.55 × 107, 7.01 × 107, 2.21 × 107 and 6.92 × 106 genome copies mg-1, respectively. Moreover, the composite could effectively adsorb the four types of virus particles from coastal, tap, and river water. In addition, concentrating the virions using CTAB functionalized rGO-Fe3O4 composites before qPCR analysis significantly improved the detection limit. The results indicate that viruses are captured on the surface of CTAB functionalized rGO-Fe3O4 composites through electrostatic interactions and the intrinsic adsorption ability of rGO. Overall, CTAB-functionalized rGO-Fe3O4 composites are promising materials for the adsorption and detection of human enteric viruses as well as SARS-CoV-2 from complex aqueous environments.


Subject(s)
COVID-19 , Graphite , Adsorption , Cetrimonium , Humans , SARS-CoV-2
14.
Materials (Basel) ; 14(15)2021 Jul 29.
Article in English | MEDLINE | ID: covidwho-1335142

ABSTRACT

Due to the SARS-CoV-2 pandemic, there has been an increase in the search for affordable healthcare devices for mass testing and rapid diagnosis. In this context, this work described a new methodology for SARS-CoV-2 detection based on an impedimetric immunosensor developed using the advantageous immobilization of antibodies in the reduced graphene oxide (rGO). The rGO was obtained by chemical synthesis from the commercial graphene oxide (GO), and the materials were morphologically, electrochemically and visually characterized. The cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques were used to evaluate the fabrication steps of the immunosensor. The electrochemical immunoassay was considered for SARS-CoV-2 spike protein RBD detection using a impedimetric immunosensor and redox couple ([(Fe(CN)6)]3-/4-) as a probe. The immunosensor was effectively developed and applied in the detection of SARS-CoV-2 spike protein RBD in saliva samples.

15.
Adv Funct Mater ; 31(26): 2100801, 2021 Jun 23.
Article in English | MEDLINE | ID: covidwho-1195106

ABSTRACT

Nowadays, the main obstacle for further miniaturization and integration of nucleic acids point-of-care testing devices is the lack of low-cost and high-performance heating materials for supporting reliable nucleic acids amplification. Herein, reduced graphene oxide hybridized multi-walled carbon nanotubes nano-circuit integrated into an ingenious paper-based heater is developed, which is integrated into a paper-based analytical device (named HiPAD). The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is still raging across the world. As a proof of concept, the HiPAD is utilized to visually detect the SARS-CoV-2 N gene using colored loop-mediated isothermal amplification reaction. This HiPAD costing a few dollars has comparable detection performance to traditional nucleic acids amplifier costing thousands of dollars. The detection range is from 25 to 2.5 × 1010 copies mL-1 in 45 min. The detection limit of 25 copies mL-1 is 40 times more sensitive than 1000 copies mL-1 in conventional real-time PCR instruments. The disposable paper-based chip could also avoid potential secondary transmission of COVID-19 by convenient incineration to guarantee biosafety. The HiPAD or easily expanded M-HiPAD (for multiplex detection) has great potential for pathogen diagnostics in resource-limited settings.

16.
Adv Mater ; 33(7): e2006647, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-985908

ABSTRACT

Rapid diagnosis is critical for the treatment and prevention of diseases. An advanced nanomaterial-based biosensing platform that detects COVID-19 antibodies within seconds is reported. The biosensing platform is created by 3D nanoprinting of three-dimensional electrodes, coating the electrodes by nanoflakes of reduced-graphene-oxide (rGO), and immobilizing specific viral antigens on the rGO nanoflakes. The electrode is then integrated with a microfluidic device and used in a standard electrochemical cell. When antibodies are introduced on the electrode surface, they selectively bind with the antigens, changing the impedance of the electrical circuit which is detected via impedance spectroscopy. Antibodies to SARS-CoV-2 spike S1 protein and its receptor-binding-domain (RBD) are detected at a limit-of-detection of 2.8 × 10-15 and 16.9 × 10-15 m, respectively, and read by a smartphone-based user interface. The sensor can be regenerated within a minute by introducing a low-pH chemistry that elutes the antibodies from the antigens, allowing successive sensing of test samples using the same sensor. Sensing of S1 and RBD antibodies is specific, which cross-reacts neither with other antibodies such as RBD, S1, and nucleocapsid antibody nor with proteins such as interleukin-6. The proposed sensing platform could also be useful to detect biomarkers for other infectious agents such as Ebola, HIV, and Zika.


Subject(s)
Antibodies, Viral/immunology , COVID-19/immunology , Electrodes , Graphite/chemistry , Nanotechnology/methods , Aerosols , Antigens, Viral/immunology , Biosensing Techniques , Dielectric Spectroscopy , Electrochemical Techniques , Humans , Hydrogen-Ion Concentration , Nanostructures , Printing, Three-Dimensional , Protein Domains , Spike Glycoprotein, Coronavirus/immunology
17.
Chem Eng J ; 420: 127575, 2021 Sep 15.
Article in English | MEDLINE | ID: covidwho-898556

ABSTRACT

Virus-induced infection such as SARS-CoV-2 is a serious threat to human health and the economic setback of the world. Continued advances in the development of technologies are required before the viruses undergo mutation. The low concentration of viruses in environmental samples makes the detection extremely challenging; simple, accurate and rapid detection methods are in urgent need. Of all the analytical techniques, electrochemical methods have the established capabilities to address the issues. Particularly, the integration of nanotechnology would allow miniature devices to be made available at the point-of-care. This review outlines the capabilities of electrochemical methods in conjunction with nanotechnology for the detection of SARS-CoV-2. Future directions and challenges of the electrochemical biosensors for pathogen detection are covered including wearable and conformal biosensors, detection of plant pathogens, multiplexed detection, and reusable biosensors for on-site monitoring, thereby providing low-cost and disposable biosensors.

18.
Mikrochim Acta ; 187(8): 441, 2020 07 12.
Article in English | MEDLINE | ID: covidwho-640090

ABSTRACT

This review (162 references) focuses on two-dimensional carbon materials, which include graphene as well as its allotropes varying in size, number of layers, and defects, for their application in electrochemical sensors. Many preparation methods are known to yield two-dimensional carbon materials which are often simply addressed as graphene, but which show huge variations in their physical and chemical properties and therefore on their sensing performance. The first section briefly reviews the most promising as well as the latest achievements in graphene synthesis based on growth and delamination techniques, such as chemical vapor deposition, liquid phase exfoliation via sonication or mechanical forces, as well as oxidative procedures ranging from chemical to electrochemical exfoliation. Two-dimensional carbon materials are highly attractive to be integrated in a wide field of sensing applications. Here, graphene is examined as recognition layer in electrochemical sensors like field-effect transistors, chemiresistors, impedance-based devices as well as voltammetric and amperometric sensors. The sensor performance is evaluated from the material's perspective of view and revealed the impact of structure and defects of the 2D carbon materials in different transducing technologies. It is concluded that the performance of 2D carbon-based sensors is strongly related to the preparation method in combination with the electrical transduction technique. Future perspectives address challenges to transfer 2D carbon-based sensors from the lab to the market. Graphical abstract Schematic overview from synthesis and modification of two-dimensional carbon materials to sensor application.

19.
Med Hypotheses ; 144: 110031, 2020 Nov.
Article in English | MEDLINE | ID: covidwho-636053

ABSTRACT

The Severe Acute Respiratory Syndrome CoronaVirus 2 (SARS-CoV-2) causes the new coronavirus disease 2019 (COVID-19). This disease is a severe respiratory tract infection that spreading rapidly around the world. In this pandemic situation, the researchers' effort is to understand the targets of the virus, mechanism of their cause, and transmission from animal to human and vice-versa. Therefore, to support COVID-19 research and development, we have proposed approaches based on graphene and graphene-derived nanomaterials against COVID-19.


Subject(s)
COVID-19/prevention & control , Graphite/therapeutic use , Nanostructures/therapeutic use , Angiotensin-Converting Enzyme 2/metabolism , Animals , Disinfection , Electric Conductivity , Graphite/chemistry , Humans , Materials Testing , Molecular Dynamics Simulation , Nanomedicine , Nanoparticles , Pandemics , Personal Protective Equipment , Quantum Dots
SELECTION OF CITATIONS
SEARCH DETAIL